-0536-3297536
UF system is widely used in processing of mineral water, which features easy operation, less labor force and low running cost.
Composition of Water Treatment System
Pre-treatment System.
Pre-treatment system is composed of mechanical filter, active carbon filter and precision filter. The water temperature requires 25±3°C.
Mechanical filter can remove most of suspension, colloid and grain impurity, which can ensure initial purification of water.
UF system
UF system is composed of high-pressure pump, UF system and chemical cleaning device.
During running, UF membrane may form some deposit and chemical cleaning device is equipped for periodical cleaning to ensure stable running of UF system.
High-pressure pump is the power source of UF system. To UF system on sound running condition, high-pressure pump equips inlet/outlet pressure switch. When inlet pressure is less than set value (water lack P≤0.05Mpa) or outlet pressure is higher than set value, pressure switch send signal to PLC programming system and high-pressure pump and UF system will stop in avoidance of destroying to UF membrane because of water pressure.
UF system can wash surface of UF membrane by low-pressure timely and periodically.
Specifications for 1000L Per hour configuration
NO. | Machine name | parameters | Quantity | Remark |
1 | Raw Water Pump | CHL2-50 | 1set | NANFANG |
2 | Quartz sand filter | Φ300*1850 | 1set | FRP or SS304 |
3 | Active carbon filter | Φ300*1850 | 1set | FRP or SUS304 |
4 | Precision filter | 20”5 core | 1set | PE |
5 | ultrafitlter pump | CHL2-50 | 1set | SUS304 |
6 | Ultrafilter | 1T | 1set | Macromolecule |
7 | Ozone generator | 3g | 1set | Carbon Steel |
8 | Ozone mixer | Φ220 | 1set | SUS304 |
9 | Pure water pump | 4-40 | 1set | NANFANG |
10 | Pure water tank | 1T | 1set | User prepare |
11 | Piping and valves | mating | 1set | UPVC orSUS304 |