-0536-3297536
A. Description: RO system water treatment
Reverse osmosis, the raw water is tap water, first goes by pre-treatment, then by RO treatment. Through those treatments, can remove dissolving salt 99% and harmful materials, like particle, colloid, organic impurities, heavy metal ions, bacteria, viruses and heat source, etc. The system salt rejection rate gets 96-98%, outlet water conductivity gets ≤ 10μ S/cm² .
B. Process: RO system water treatment
Raw water+ raw water tank +Raw water pump+Quartz sand Filter + Carbon Filter + softener filter(Optional) +security filter+High Pressure Pump+ Reverse Osmosis system +pure water tank+UV sterilizer(ozone generator) +precision filter+ water supply point
C. Function: RO system water treatment
1. Manually and automatically wash RO membrane,
2. Manually wash RO memebrane with chemicals on machine,
3. Machine automatically stops when high water level of purified water, and runs when low level,
4. Multi-stage pumps protect the machine when lack of water,
5. Protection in such cases as no power, lower pressure, higher pressure, shot circuit, creepage, etc.
E. Service:
1. Installation adjustment and maintain guideline for free
2. We can manufacture machines according to your requirement, welcome OEM.
Model | CY-RO-5 |
Capacity of the purified water | 5 ton per hour ( 25° C) |
Voltage / Frequency | AC220V 18A / 380V 9A 50HZ |
Multistage Pump | CNP CDL2-180 2.2kw Autostop if Low pressure / power / water shortage |
Reverse Osmosis Main Part | S. S304 Housing with 3pcs RO membrane RO Membrane Origin USA Hydranautic or DOW |
Main Control Board | Equiped TDS / Pressure meter / Flow meter / Control buttom |
RO System Washing | 1. Back washing about 8 hours per shift 2. Chemical washing for RO membrane about 7month |
Dimension of the RO machine | 1550*900*1820 |
Post UV sterilizer UV-40W | Optional |
Post Ozone System | Optional |